SIGMA 2-16PK
General features The microprocessor-controlled electronic system ensures a wide range of adaptations of the centrifuge for various tasks. The following parameters can be set: Speed in steps of 1 or 100 rpm Relative centrifugal force RCF in steps of 1 or 10g Time between 10sec and 11h 59min max. Continuous run Short run Rotor preselection Temperature range from – 10°C to + 40°C in steps of 1°C Acceleration and deceleration curves Rotor 12148 Angle rotor for 24 x 1.5 - 2.2 ml microcentrifuge tubes, with hermetic aluminium lid, max. radius 8.2 cm, min. radius 5 cm, angle 45°, max. speed (min -1)...
Autester ST DRY-PV-B18
General features Sterilization chamber and cover in stainless steel External epoxy coated case External steam generator to the sterilization chamber Operations digital control Specific programs for testing and autoclave diagnosis Large backlight LCD display Air inlet filter to the camera Water tank RS-232 output for PC or printer connection
OSMOMAT 030
General features Automatic calibration: no manual adjustment of a potentiometer is required No ice formation in the lower cooling system: reliable measurements even for long working periods Measuring time approx. one minute: valuable in case of serial measurements Automatic measuring: simple operation Minimum sample volume: 50 µl standard Disposable plastic measuring vessels Air cooling: no water supply needed, electronic wall-socket suffices Latest electronic engineering: microprocessor controlled, automatic determination, display and storage of the result The upper front panel is clearly...
Selecta Med20
General features Pressure regulator thermostat of 1 and 2 bar Temperatures 121°C and 134°C AISI 304 stainless steel external case and top Stainless steel chamber and lid, with easy opening INCOLOY special stainless steel heater element, which provides long life, low corrosion and high temperatures resistance Automatic atmospheric purge Safety device to prevent lid opening Technical data
Zeiss Axio Observer Z1m (Zeiss)
Illumination t modes Transmission Reflection: bright field, dark field, fluorescence Components 5x, 10x, 20x, 50x and 100x HD DIC objectives 63x immersion objective Motorized stage Heating plate (r.t. to 99 °C)

Microbiology space

Telstar BIO II A
General features 70% recirculating down flow enclosure Class II A/B3 equipped with two high efficiency HEPA filters: HEPA filtered laminar airflow Class 10, which is recirculated in the work zone, creates an ultra-clean work environment for product protection. A room air barrier at the front opening prevents escape of pathogens into the worker’s area. Exhaust HEPA filter provides safety to environment. Stove-enamel coated steel cabinet Easy access for working and cleaning Working space in stainless steel AISI 304 Segmented working surface Laminated safety front window with gas springs Two HEPA...
Incubator Forma Series II Water Jacket
General features Polished stainless steel interior In-chamber HEPA air filtration system Heating: The temperature of the work chamber can be regulated within a range of 10°C to 50°C. Water Jacket Technology: Maximum thermal stability and quick recovery are assured with the unique triple wall construction, providing superior protection against temperature loss in the event of an unexpected power outage. Humidification: The atmosphere in the work chamber is humidified through the evaporation of water held in a basin at the bottom of the inner casing.
Orbital shaker Stuart Mini SSM1
General features Smooth orbital shaking action Orbit of 16 mm is ideal for larger samples, for example multi well plates Built-in digital timer Variable speed control to 300 rpm Supplied with non-slip mat for multi-well plates etc. Optional accessory cradle system for flasks and bottles Technical data
Heraeus Biofuge pico
Technical Data
Microwave ProClean 310
Technical data Voltage: 230 V, 50 Hz Power levels: 6 Max. power: 700 W Dimensions: 44.5 x 35.5 x 25.5 cm

Cell culture space

CO2 incubator HERAcell
General features The test chamber atmosphere can be regulated with respect to its temperature and CO 2 concentration. The evaporation of water from the water reservoir creates a high and constant relative humidity. Heating: An air jacket heating systems allows the test chamber temperature to be adjusted from +3°C to 55°C. Gas supply: The CO 2 content of the test chamber atmosphere can be adjusted within a range from 0 - 20 %. A stainless steel fan wheel circulates and mixes the test chamber atmosphere. Sensor block contains sensors for temperature, gas flow regulation, and temperature...
Microcentrifuge Eppendorf 5415C
Technical data Power supply: 220 V/50 Hz Power requirement: 250 W Rotational speed: Continuously adjustable from 1000 to 14000 rpm Acceleration / deceleration time: 10 / 15 sec Places / volume: 18 x 1.5 / 2 ml Max. permissible load: 18 x 4.2 g Max. rotational speed: 14000 rpm Max. centrifugal force: 16000 RCF Angle: 45 Dimensions: 28.0 x 21.0 x 28.5 cm (height x width x depth) Weight: 6.5 kg
CO2 incubator Function line BB16
General features The test chamber atmosphere can be regulated with respect to its temperature and CO 2 concentration. The evaporation of water from the water reservoir creates a high and constant relative humidity. The inner casing and fittings are made of copper. Heating: The temperature of the work chamber can be regulated within a range starting at +6°C above room temperature up to 50°C. Gas supply: The CO 2 saturation of the atmosphere in the work chamber can be regulated within the range of 0 % to 20 %. A stainless steel fan wheel circulates and mixes the test chamber atmosphere...
Optical microscope Zeiss TELAVAL 31
General features Fixed Köhler lighting with a numeric aperture of 0.4 and an operating distance of 55mm Bright field overview lighting for large specimen fields and for receptacle heights up to 175mm Light source: halogen lamp S 5 A 6 V 25 W Eyepiece: 10x Objective lenses: 10x, 20x The ICN2 also has in its Research Support Facilities the following optical microscopes that can be useful for users of the Biolab Facility: Axio Observer Z1m optical microscope (ZEISS), a high resolution inverted microscope that can be used for epifluorescence, transmitted and reflected light illumination, bright...
Grant water bath
General features Temperature range: ambient +5°C to 95°C operation Stability: ±0.5°C Temperature setting: digital
HERAsafe HS12
General features Vertical laminar air flow and air intake (air curtain) across front opening Modular design for flexible, individually orientated use Motor-driven front window: Optimum protection through hermetically sealing, aerosol tight lock Permanent monitoring of all relevant safety functions via monitor control system Equipped with a High Efficiency Particle Air Filter (HEPA) H 14 which guarantees a minimum absorption of 99.999% on 0.3 µm particles
Telstar AV-100 Vertical Laminar Flow Bench
General features Supplied with working area CLASS 10 as defined by U.S. Fed. Std. 209 a B.S. 5295 Specially designed for handling of non-pathogenic biological samples, cell and tissue cultures, controls in microbiology, pharmaceutical products preparation, electronics, optics and more Cabinets made of stove-enamel coated steel Modern and accurate design makes it possible to change the filters from inside the cabinet, having reduced external dimensions with suitable working area Polished stainless steel working surface divided into three parts for easy removal for sterilizing Removable side...